TZ CARD: Computational Time Control
Required
Card Description: Used to control the simulation time.
Field
Variable
Value Description
ΤΖ
0,C1-2
IC1
Card group identifier
≥0
3
NTTS
Maximum number of cycles
<0
Default = 0
≥0
Length of a time step for SED2D WES simulation
1
DT
(decimal hours). Note: The capability exists to
specify a time step that is different from the RMA2
time step when using a dynamic RMA2 solution
file. However, this is NOT RECOMMENDED. If
the SED2D time step is less than the RMA2 time
step then a linear interpolation will be performed to
evaluate the velocities at the intermediate time steps.
The SED2D time step cannot be larger than the
RMA2 time step. WARNING: It is highly
recommended that the SED2D time step be set
exactly equal to the RMA2 time step. Severe
accuracy errors can result from using an interpolated
flow field.
<0
Default = 0.0
≥0
2
TMAX
Maximum time for a simulation (decimal hours)
<0
Default = 0.0
NOTE: It is highly recommended that the SED2D time step be set exactly
equal to the RMA2 time step
Run Control TZ Card 129
Users Guide To SED2D-WES