D-R-A-F-T
TH CARD: Timing of the Hydrodynamic File
Required
Card Description: Used to define the RMA2 time steps used
Field
Variable
Value Description
0, C 1-2
IC1
TH
Card group identifier.
0, C 3
IC3
b/
Card type identifier.
Time (hr) to subtract from the RMA2 time to define
1
TCORR
Real
SED2D time 0.
RMA2 Time value of the last time step on RMA2
2
TEND
Real
file.
≥0
DT_REPE
Time increment for RMA2 solution file rewind
3
AT
(decimal hours). When using a repeating
hydrodynamic solution (such as a repeating tide or a
steady state hydrodynamic solution) the time
increment between the last time step in the RMA2
solution file and the first time step of the rewound
RMA2 solution file must be specified. For steady
state hydrodynamics let DT_REPEAT = TMAX to
avoid re-reading the RMA2 file every time step.
<0
Default to the delta time step value on the TZ card
(DT variable)
See also TZ
CARD: Computational Time Control
122 Run Control TH Card
Users Guide To SED2D-WES