D-R-A-F-T
GE CARD: Grid, Element Connection Table
Optional
Card Description: The element connection table will usually be provided by the
GFGEN pre-processor and will reside on logical unit ING on the $L1-card. If so,
omit GE and GNN cards.
Field
Variable
Value Description
0, C 1-2
IC1
GE
Card group identifier.
1
J
+
Element number
Up to 8 node numbers for element J, listed
2-9
NOP (J,K)
+
counterclockwise around the element starting from
any corner.
10
IMAT (J)
+
Element material type
Direction of eddy viscosity tensor in RMA2.
11
TH (J)
+
Optional, may be specified on the GV card.
Radians, counter-clockwise from the X-axis. For
1D elements, the direction is automatically aligned
with the orientation of the 1D element
NOTE: Use GE and GNN cards only to create simple grids for model testing.
SED2D WES does not contain grid generation or band width optimization routines.
96 Run Control GE Card
Users Guide To SED2D-WES