07/00
TZ CARD
COMPUTATION TIME CONTROL
TZ CARD
Required for dynamic calculations
Field
Variable
Value
Description
0,C1-2
IC1
TZ
Card group identifier
1
NCBC
+
Not used. Fill with a zero.
2
NSTART
+
Starting time step - used to skip through the boundary condition data
file for restart.
-
Read starting time step from HOTSTART file
3
NCYC
+
Number of time steps to be simulated.
4
DELT
+
Initial length of a time step (hours) OR the time increment (hours) for
this step of a dynamic simulation.
5
TMAX
+
Maximum time for a simulation. This is the total elapsed time,
including the time written to the hotstart file (if one is present)
6
ALPHA
+
Variable used to calculate the temporal derivative
-
Negative value defaults to 1.0
(Value of 1.5 is second order Taylor expansion)
41